Mfg Part Number: 5496267P2 | Manufacturer: General Electric Inc | NSN : 5910-01-114-7001 |
NIIN : 011147001 | Item Name : capacitor fixed ele | CAGE Code : 08771 |
FSC : 5910 Capacitors |
Thank you for your continued interest in the 5496267P2 part currently available on National Stock Number Parts. Here, our customers will find our NSN RFQ Page for Capacitor Fixed Ele parts under FSC 5910 Capacitors with the NSN 5910-01-114-7001, among others from the manufacturer General Electric Inc. For particular equipment, such as part number 5496267P2, the submission of a completed RFQ form will provide customers with a quote on any desired part in just 15 minutes or less. Upon receival, our expert market representatives will use your offered information to construct a quote paramount to your operations with rapid turnaround times and cost savings at our forefront.
As our robust supply chain stretches across the United States, Canada, and the United Kingdom, we are able to supply entities facing Aircraft on Ground (AOG) delays or other unique time constraints with expedited shipping on select NSN 5910-01-114-7001 items for immediate procurement. Operating as an AS9120B, ISO 9001:2015, and FAA AC 00-56B certified enterprise, products listed on our database are upheld to rigorous quality assurance testing, inspection, and cross-referencing before shipment. Functioning as the only independent distributor with a NO CHINA SOURCING pledge, you can depend on National Stock Number Parts for authentic 5496267P2 NSN part, which are listed alongside the CAGE Code 08771 by General Electric Inc.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-01-114-7001 Item Description: Capacitor Fixed Ele | 5910 | 011147001 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5496267P2 | 1 | C | B |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES, AXIAL TERMINALS |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.250 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.185 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.485 INCHES NOMINAL |
AEBT | TERMINAL DIAMETER | 0.019 INCHES MINIMUM AND 0.026 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
AECQ | ELECTRICAL POLARIZATION | POLARIZED |
CQBQ | CAPACITANCE VALUE PER SECTION | 47.000 MICROFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -30.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQLH | DC LEAKAGE AT MAXIMUM OPERATING TEMP | 113.0 MICROAMPERES |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 6.0 DC SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -5.00/+5.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | METAL |
CWNJ | CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 6.0000 |
CWQC | EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS | 1.70 |
CWQH | DC LEAKAGE AT REFERENCE TEMP | 11.300 MICROAMPERES |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
CWSZ | CASE INSULATION MATERIAL | PLASTIC |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote